GENERAL INFORMATION
|
 |
| Model Type |
KING CS SERIES |
 |
| Model Name |
KIN-625CS |
 |
 |
AC INPUT
|
 |
| AC Input Capacity on Battery |
625VA |
 |
| AC Input Voltage |
120V +/- 25% |
 |
| AC Input Frequency |
50 or 60 Hz +/-10% (auto sensing) |
 |
 |
OUTPUT
|
 |
| Output Voltage On Battery |
Simulated sine wave at 120V +/- 5% |
 |
 |
AC OUTPUT
|
 |
| AC Output Voltage |
Sine wave at 120V +/-10% |
 |
| AC Output Frequency |
50 or 60 Hz +/- 1% |
 |
| AC Output Voltage Regulation |
AVR automatically increase output voltage 15% while nominal -9% to -25% utility voltage be connected; AVR automatically decrease output voltage 13% while nominal +9% to +25% utility voltage be connected |
 |
| AC Output Transfer |
2/4 milliseconds, including detection time |
 |
 |
PROTECTION
|
 |
| Protection Spike |
480 Joules, 2ms |
 |
| Protection Overload |
UPS automatic shutdown if overload exceeds 110% nominal at 60 sec and 130% at 3 sec |
 |
| Protection Unit |
Circuit breaker for overload & short circuit protection |
 |
| Protection 10 BaseT |
Network (UTP, RJ-45) compatible jacks |
 |
| Protection Short Protection |
UPS output cut off immediately or input circuit breaker protection |
 |
 |
BATTERY
|
 |
| Battery Type |
Sealed, maintenance-free lead acid batteries with 3-6 years typical lifetime |
 |
| Battery Typical |
6 hours (to 90% of full capacity) |
 |
| Battery Protection |
Auto discharge protection |
 |
 |
BACKUP TIME
|
 |
| Battery Backup Time Full Load |
6 minutes |
 |
| Battery Backup Time Half Load |
13 minutes |
 |
 |
PHYSICAL
|
 |
| Physical Weight kgs Tower |
6.5 |
 |
| Physical Weight lbs Tower |
14.3 |
 |
| Physical Shipping Weight kgs |
7.0 |
 |
| Physical Shipping Weight lbs |
15.4 |
 |
| Physical Dimension mm Tower |
97x320x135 |
 |
| Physical Dimension inch Tower |
3.8x12.5x5.3 |
 |
 |
ALARM
|
 |
| Alarm Battery Backup |
Slow beeping sound (about 0.47 Hz) |
 |
| Alarm Battery Low |
Rapid beeping sound (about 1.82 Hz) |
 |
| Alarm Overload |
Continuously beeping sound |
 |
 |
INTERFACE
|
 |
| Interface RS-232 |
Detect battery low; Schedule UPS on/off; Display AC input/output power status |
 |
 |
ENVIRONMENT
|
 |
| Environment Ambient |
3500 meters max. elevation, 0-95% humidity non-condensing, 0-40 deg C |
 |
| Environment Audible |
<40dBA (1 meter from surface) |
 |
| ShowOrder |
0 |
 |
 |